PA house technical specification |
No. |
Sort |
Name |
Specification |
1 |
Product Type |
Degree of Standardization |
custom-made product,design and manufacture according to clients requirement |
2 |
Size |
Length (m): |
No limited, increase expansion joint when length more than 200m. |
3 |
Width(m): |
single span should be less than 12m, an arbitrary width could make by union spans |
4 |
Heigth(m): |
single floor≤5m, two or three floors, average height ≤4m |
5 |
Roof slope: |
slope is 1:10~1:5 |
6 |
Floors: |
less than 3 floors |
7 |
Standard equipment |
Ground channel |
Galvanized steel panle compression, thickness is 0.8mm |
8 |
Post |
Inside post is steel square pipe,material is Q235,components surface make antirust process,and decorate with color steel compression parts. |
9 |
Roof beam |
roof truss consist of thin sharpe steel by welding,component surface make antirust process |
10 |
Purlin |
purlin is Ctype steel,material is Q235,components surface make antirust process. |
11 |
Wall beam |
wall beam is Ctype steel or square pipe,material is Q235,component surface make antirust process |
12 |
Floor |
made of floor master beam, secondary beam and floor surface plate(plywood) |
13 |
wallboard |
50~150mm thickness double surface color steel sandwich panel,white color |
14 |
roof board |
50~150mm thickness double surface color steel corrugated sandwich panel,blue or red color |
15 |
door |
color steel sandwich panel door,size:750mm*2000mm; |
16 |
window |
PVC sliding window, with steel screen. |
17 |
Options |
Ceiling |
mineral wool acoustic panel,aluminium buckle panel,PVC ceiling |
18 |
Elevation floor |
Design based on local weather condition. |
19 |
Canopy |
color steel sheet or color steel sandwich panel canopy |
20 |
door |
compound wooden door,security door,aluminium alloy door |
21 |
Electrical accessories |
Supply plan,design and construction according to relevant national norms(220V,50Hz,with lamp, switches and multi-function sockets.) |
22 |
Water plumbing accessories |
Supply plan,design and construction according to relevant national norms |
23 |
Sanitary ware |
Supply according to customer needs |
24 |
Furniture and electric appliance |
Supply according to customer needs |
25 |
Design technical data |
Roof dead load |
0.3KN/sqm |
26 |
Roof live load |
0.5KN/sqm |
27 |
Floor dead load |
0.5KN/sqm |
28 |
Floor live load |
2KN/sqm |
29 |
Wind load |
12degree,120km/h(strengthen the steel frame when the wind is bigger than this data) |
30 |
Earthquake resistant intensity |
8 degree |
31 |
Used for temperature |
Celsius: from -25 to+50 (change the design when the temperature is lower than Celsius -25) |
32 |
Installation |
Installation tools |
electric drill, electric hammer,spanner,screwdriver,pulling rivet etc, house installation need electric power. |
33 |
Installation efficiency |
Four skilled labor one day can erect 40m2’s house body |
34 |
Transport |
container |
each 40ft container could load 130~150Sqm house body material |