PB house technical specification
|
No.
|
classification
|
Name
|
Specification & Parameter
|
1
|
Type
|
standardization
|
custom made products,design and manufacture according to client’s demand
|
2
|
disassembly and assembly
|
not suitable for assemble and disassemble,lower repeating utilization factor.
|
3
|
Specification
|
Length:
|
No limited, increase expansion joint when length more than 200m.
|
4
|
Width:
|
≤11m
|
5
|
Height:
|
≤3.0m
|
6
|
Roof slope:
|
double slope,1:6-1:4
|
7
|
Floors:
|
1 floor
|
8
|
Standard
|
Ground channel
|
Galvanized steel panel pressure,steel panel thickness is 0.8mm
|
9
|
Post
|
Outdoor post is square steel pipe,material is Q235,components make bottom and surface painted process.
|
10
|
roof beam
|
Triangle roof frame is welded by square steel pipe,components surface is made rust-proof process.
|
11
|
purlin
|
Purlin is square steel pipe,material is Q235,components surface is made rust-proof process.
|
12
|
wallboard
|
75mm~150mm thickness color steel sandwich panel, white color
|
13
|
roof board
(Ceiling board)
|
75~150mm thickness color steel sandwich panel, white color
|
14
|
roof tiles
|
V35-125-350 color steel tiles,blue or red color
|
15
|
door
|
sandwich panel door,size:750mm*2000mm;
|
16
|
window
|
PVC sliding window,conch model
|
17
|
Options
|
ceiling
|
roof board is also ceiling board, so this house don’t need to make ceiling again.
|
18
|
canopy
|
color steel sheet or color steel sandwich panel canopy
|
19
|
door
|
compound wooden door,security door,aluminium alloy door
|
20
|
Electrical accessories
|
Supply plan,design and construction according to relevant national norms (220V,50Hz,with lamp, switches and multi-function sockets.)
|
21
|
Water plumbing accessories
|
Supply plan,design and construction according to relevant national norms
|
22
|
Sanitary ware
|
Supply according to customer needs
|
23
|
Furniture and electrical appliance
|
Design according to client’s needs
|
24
|
Desigh
Parameter
|
roof dead load
|
0.3KN/Sqm
|
25
|
roof live load
|
0.5KN/Sqm
|
26
|
wind load
|
9 degree,wind load:0.35KN/Sqm,design speed:24m/S(Chinese standard)
|
27
|
Earthquake resistant intensity
|
6 degree
|
28
|
used temperature
|
Celsius:-25~+50
|
29
|
Installation
|
Tools
|
electric drill,pulling rivet,electric hammer,spanner,screwdriver etc,need power to install the house
|
30
|
Efficiancy
|
Four skilled labor one day can erect 40m2’s house body
|
31
|
Transport
|
Container
|
each 40ft container could load 130~150Sqm house body material
|